Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1235102.015
Citation: 01004B
Citation Type: Serious
Abatement Date: 08/07/2017 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/20/2017
Nr Instances: 7
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0729300
Contest Date:
Final Order: 07/14/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/14/2017 | $0.00 | 08/07/2017 | Serious | |
Penalty | Z: Issued | 06/20/2017 | $0.00 | 08/07/2017 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented, and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: At 687 Fee Fee Road, Maryland Heights, MO, on 05/25/17, the employer did not document the specific procedures for the following equipment: a/ Philadelphia T Ramrail Vertical Baler. b/ Excel Twin Ram Series Baler. c/ Caterpillar Fork Truck, m/n T40D, 8EB10453. d/ Caterpillar Fork Truck, m/n GC25, s/n 4EM-00351. e/ Toyota Electric Fork Truck, m/n 7FBEU15, s/n 19902. f/ Toyota Fork Truck, m/n 7FBCU20, s/n 69248. g/ Yale Fork Truck, m/n ERP030TGN36TE082, s/n E807N04109Z.