Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1234547.015
Citation: 01004B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/27/2017
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 11/28/2017
Gravity: 10
Report ID: 0523900
Contest Date:
Final Order: 11/24/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 10/27/2017 | $0.00 | 11/28/2017 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program were understood by authorized, affected, and other employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls were acquired by authorized employees: (a) Throughout the facility; Authorized level energy isolation (lockout) training was not provided for employees to inform them of the means and methods to use for isolating hazardous energy sources before they performed servicing, maintenance, and setup activities on equipment including, but not limited to, extrusion presses which had multiple energy sources including pneumatic, hydraulic, electric, and thermal. (b) Throughout the facility; Affected level energy isolation (lockout) training was not provided to inform employees of the purpose and function of the energy control program.