Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1230602.015
Citation: 01004B
Citation Type: Serious
Abatement Status:
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/02/2017
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 11/16/2017
Gravity: 10
Report ID: 0627700
Contest Date:
Final Order: 10/30/2017
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/30/2017 | $0.00 | 11/16/2017 | Serious | |
| Penalty | Z: Issued | 10/02/2017 | $0.00 | 11/16/2017 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: Rock crusher: On or about May 2, 2017, employees operated a rock crusher during the recycling of concrete pieces and an employee entered the crusher hopper prior to shutting down using procedures established for the machine or equipment. This exposed the employee caught in and struck by hazards.