Violation Detail
Standard Cited: 19260757 E02 Open web steel joists.
Inspection Nr: 1183716.015
Citation: 01004B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,873.00
Current Penalty: $0.00
Issuance Date: 02/07/2017
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 02/13/2017
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 02/24/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/24/2017 | $0.00 | 02/13/2017 | Serious | |
Penalty | Z: Issued | 02/07/2017 | $8,873.00 | 02/13/2017 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1926.757(e)(2): Except for paragraph (e)(4) of this section, no construction loads are allowed on the steel joists until all bridging is installed and anchored and all joist-bearing ends are attached. Located within Sequence 17 Music Wing on October 11, 2016 metal decking construction load bundle(s) were allowed to be placed on 1926.757 Table A covered type short span open web steel bar joist series 22K7-J240 exceeding 40 foot 7 inches spans were erected without all erection and horizontal bridging being installed and anchored and all joist-bearing ends secured with welded attachment anchorage exposing employees to the hazard of being struck by unintentional displacement of open web steel joist which exceeded the carrying capacity of the steel joist within pocketed bearing points.