Violation Detail
Standard Cited: 19100147 C04 II D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1150717.015
Citation: 01004B
Citation Type: Serious
Abatement Date: 08/25/2016 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/11/2016
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): R
Gravity: 5
Report ID: 0112600
Contest Date:
Final Order: 07/22/2016
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/22/2016 | $0.00 | 08/25/2016 | Serious | |
Penalty | Z: Issued | 07/11/2016 | $0.00 | 08/25/2016 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures: Tank EX-1, Kanzaki Specialty Papers, 20 Cummings Street, Ware, Massachusetts; May 27, 2016, The energy control procedure for tank EX-1 in the mixing department did not include requirements for testing to verify the effectiveness of lockout devices and other energy control measures.