Violation Detail
Standard Cited: 19100147 C05 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1064409.015
Citation: 01004B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/24/2015
Nr Instances: 5
Nr Exposed: 3
Abatement Date: 12/03/2015
Gravity: 5
Report ID: 0729300
Contest Date:
Final Order: 08/21/2015
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/21/2015 | $0.00 | 12/03/2015 | Serious | |
Penalty | Z: Issued | 07/24/2015 | $0.00 | 09/10/2015 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources: Inside of the Fabrication Department, employee(s) were not provided with the necessary hardware to effectively isolate the following machines from their energy sources: a/ K.R. Wilson Hydraulic Press, m/n 3700V2-B, s/n 2051. b/ Bliss Mechanical Punch Press, m/n 5012, unknown s/n. c/ Willis-Bergo Radial Arm Drill, m/n FS1000, unknown s/n. Inside of the Machine Shop, employee(s) were not provided with the necessary hardware to effectively isolate the following machines from their energy sources: a/ W.B. Knight Milling Machine, m/n J, unknown s/n. b/ HAAS Vertical Machining Center, m/n BF2, s/n 2080.