Violation Detail
Standard Cited: 19100027 E04 Scaffolds and rope descent systems.
Inspection Nr: 1006716.015
Citation: 01004B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/29/2015
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 05/19/2015
Gravity: 5
Report ID: 0522500
Contest Date:
Final Order: 05/22/2015
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/22/2015 | $0.00 | 05/19/2015 | Serious | |
Penalty | Z: Issued | 04/29/2015 | $0.00 | 05/19/2015 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1910.27(e)(4): "Pitch greater than 90 degrees." Ladders having a pitch in excess of 90 degrees with the horizontal are prohibited. a. In the back storage bin area, the employer had a fixed ladder with a cage. The section of the ladder below the cage was angled in excess of 90 degrees. Employees were exposed to a fall hazard of 11 feet.