Violation Detail
Standard Cited: 19260651 I01 Specific Excavation Requirements.
Inspection Nr: 996709.015
Citation: 01004A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,000.00
Current Penalty: $7,000.00
Issuance Date: 03/20/2015
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 03/26/2015
Gravity: 10
Report ID: 0215000
Contest Date: 03/25/2015
Final Order: 11/06/2015
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 11/06/2015 | $7,000.00 | 03/26/2015 | Serious | |
| Penalty | C: Contested | 04/13/2015 | $7,000.00 | 03/26/2015 | Serious | |
| Penalty | Z: Issued | 03/20/2015 | $7,000.00 | 03/26/2015 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1926.651(i)(1): Where the stability of adjoining buildings, walls, or other structures was endangered by excavation operations, support systems such as shoring, bracing, or underpinning were not provided to ensure the stability of such structures for the protection of employees: a) Temporary shoring/ bracing was not provided to support the unsupported overhanging foundation wall when the employer was excavating underpin sections, including section D14. The face of the wall was 18 inches wider than the wall footing causing an unsupported overhang condition. Location: 326 W 37th Street, New York, N.Y. On or about 9/23/2014 NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.