Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 952524.015
Citation: 01004A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,000.00
Current Penalty: $0.00
Issuance Date: 06/04/2014
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 07/23/2014
Gravity: 10
Report ID: 0625700
Contest Date:
Final Order: 06/26/2014
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/26/2014 | $0.00 | 07/23/2014 | Serious | |
| Penalty | Z: Issued | 06/04/2014 | $7,000.00 | 06/23/2014 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about December 13, 2013, at Cajun Sugar in New Iberia, LA; the employer did not: a) Isolate the Crusher Donnely Chute and/or mill roller from all energy sources; b) Apply a lockout or tagout device to secure the Crusher Donnely Chute and/or mill roller from all energy sources; and/or c) Verify isolation of the Crusher Donnely Chute and/or mill roller from all energy sources.
Translate