Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 911293.015
Citation: 01004A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $2,380.00
Current Penalty: $1,428.00
Issuance Date: 11/26/2013
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 12/09/2013
Gravity: 5
Report ID: 0627510
Contest Date:
Final Order: 12/11/2013
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/11/2013 | $1,428.00 | 12/09/2013 | Serious | |
Penalty | Z: Issued | 11/26/2013 | $2,380.00 | 12/09/2013 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): On or about June 5, 2013, employees were exposed to caught-in-between hazards in that the employer did not guard a pulley.