Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 903994.015
Citation: 01004A
Citation Type: Other
Abatement Date: 08/27/2013 2
Initial Penalty: $4,250.00
Current Penalty: $2,500.00
Issuance Date: 08/01/2013
Nr Instances: 15
Nr Exposed: 37
Related Event Code (REC):
Gravity:
Report ID: 0419400
Contest Date:
Final Order: 08/27/2013
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/27/2013 | $2,500.00 | 08/27/2013 | Other | |
Penalty | Z: Issued | 08/01/2013 | $4,250.00 | 08/27/2013 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) 820 Highway 7 North in Holly Springs, MS - On or about April 30, 2013, periodic inspections of the energy control procedures were not being performed at least annually on equipment such as but not limited to extruders, air compressors, MTI mixer, dry blend cooler, etc.