Violation Detail
Standard Cited: 19100119 F01 ID Process safety management of highly hazardous chemicals.
Inspection Nr: 314506338
Citation: 01004A
Citation Type: Serious
Abatement Status: I
Initial Penalty: $4,500.00
Current Penalty: $2,531.00
Issuance Date: 01/05/2011
Nr Instances: 4
Nr Exposed: 4
Abatement Date: 01/10/2011
Gravity: 10
Report ID: 0855610
Contest Date:
Final Order:
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/23/2011 | $2,531.00 | 01/10/2011 | Serious | |
| Penalty | Z: Issued | 01/05/2011 | $4,500.00 | 01/10/2011 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard: REFINERY
1910.119(f)(1)(i)(D)* Operating procedures. The employer shall develop and implement written operating procedures that provide clear instructions for safely conducting activities involved in each covered process consistent with the process safety information and shall address at least the following elements. Steps for each operating phase: Emergency shutdown including the conditions under which emergency shutdown is required, and the assignment of shutdown responsibility to qualified operators to ensure that emergency shutdown is executed in a safe and timely manner: Not all operating procedures for the FCC Unit (NOP, ESP, Start-Up, & SOP) allowed qualified operators to conduct an emergency shutdown procedure.