Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1814556.015
Citation: 01004A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $14,895.00
Current Penalty: $11,000.00
Issuance Date: 05/30/2025
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 06/11/2025
Gravity: 10
Report ID: 0317700
Contest Date:
Final Order: 06/10/2025
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/10/2025 | $11,000.00 | 06/11/2025 | Serious | |
Penalty | Z: Issued | 05/30/2025 | $14,895.00 | 06/11/2025 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Wash Area - On or about March 31, 2025, the employer did not inspect lockout/tagout procedures annually on the Lift B (Model: CB214). ABATEMENT CERTIFICATION AND DOCUMENATION REQURED