Violation Detail
Standard Cited: 19100219 B02 Mechanical power-transmission apparatus.
Inspection Nr: 1805624.015
Citation: 01004A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $14,895.00
Current Penalty: $7,447.50
Issuance Date: 07/09/2025
Nr Instances: 24
Nr Exposed: 4
Abatement Date: 08/08/2025
Gravity: 10
Report ID: 0830400
Contest Date:
Final Order: 08/05/2025
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/05/2025 | $7,447.50 | 08/08/2025 | Serious | |
| Penalty | Z: Issued | 07/09/2025 | $14,895.00 | 08/08/2025 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1910.219(b)(2):Cranks and connecting rods. Cranks and connecting rods, when exposed to contact, shall be guarded in accordance with paragraphs (m) and (n) of this section, or by a guardrail as described in paragraph (o)(5) of this section. (a)National Food NW LLC, at 25351 National Avenue, Plankinton, SD 57368: On or about and at times prior to February 21, 2025, the employer did not ensure the cranks and connecting rods on each side of the 12 Egg Packager stations of the Diamond 8200 Egg Packager was guarded. This condition exposed employees to caught-in and amputation hazards associated with the unguarded rotating parts.