Violation Detail
Standard Cited: 19100147 C04 II D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1796933.015
Citation: 01004A
Citation Type: Serious
Abatement Status:
Initial Penalty: $14,895.00
Current Penalty: $14,895.00
Issuance Date: 03/28/2025
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 05/14/2025
Gravity: 10
Report ID: 0418400
Contest Date: 04/17/2025
Final Order:
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | C: Contested | 04/21/2025 | $14,895.00 | 05/14/2025 | Serious | |
Penalty | Z: Issued | 03/28/2025 | $14,895.00 | 05/14/2025 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control. (a) In the kettle room - On or about October 2, 2024, the employer exposed employees to struck-by hazards, in that, the energy control procedures for shutdown of equipment associated with the heat exchangers did not clearly and specifically outline the steps to verify the effectiveness of lockout devices or release of stored energy within the system.