Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1793646.015
Citation: 01004A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,768.00
Current Penalty: $8,000.00
Issuance Date: 05/19/2025
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 06/30/2025
Gravity: 5
Report ID: 0336000
Contest Date:
Final Order: 06/13/2025
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/13/2025 | $8,000.00 | 06/30/2025 | Serious | |
Penalty | Z: Issued | 05/19/2025 | $9,768.00 | 06/13/2025 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a.) Viking Tool & Gage, Inc. 11210 State Highway 18 Conneaut Lake, PA 16316: on or about 12-05-2024, and times prior thereto: Employees perform servicing and maintenance on equipment including, but not limited to, the Bliss 60-ton press machine #PN21 in the Stamping Area without periodic inspections of energy control procedures occurring or being certified. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.