Violation Detail
Standard Cited: 19261203 D
Inspection Nr: 1773943.015
Citation: 01004A
Citation Type: Serious
Abatement Date: 03/11/2025 2
Initial Penalty: $6,620.00
Current Penalty: $6,620.00
Issuance Date: 02/06/2025
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): A
Gravity: 10
Report ID: 0830400
Contest Date:
Final Order: 03/03/2025
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/03/2025 | $6,620.00 | 03/11/2025 | Serious | |
Penalty | Z: Issued | 02/06/2025 | $6,620.00 | 03/11/2025 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1926.1203(d):The employer did not implement a written permit space program as required by the standard after it decided that employees it directs will enter a permit space: a)Heartland Tank Inc. at 21242 461st Avenue, Volga, SD 57071: On or about and at times prior to September 7, 2024, the employer did not ensure that a permit space program was written and implemented prior to employees entering the permit required confined space. As a result, two employees entered the oxygen deficient permit required confined space of a Harvestore Silo and died as a result. This condition exposed employees to hazards associated with permit required confined spaces such as but not limited to entering spaces with an oxygen deficient atmosphere as a result of nitrogen dioxide off-gassing.