Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1728171.015
Citation: 01004A
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $9,795.00
Current Penalty: $9,000.00
Issuance Date: 08/07/2024
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 08/28/2024
Gravity: 5
Report ID: 0627700
Contest Date:
Final Order: 08/29/2024
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/29/2024 | $9,000.00 | 08/28/2024 | Other | |
Penalty | Z: Issued | 08/07/2024 | $9,795.00 | 08/28/2024 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about February 10, 2024, at diesel fuel dispensers, adequate energy control procedures were not utilized by employees when changing a filter on diesel pump 19.