Violation Detail
Standard Cited: 19100147 C05 II C 1 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1716204.015
Citation: 01004A
Citation Type: Other
Abatement Status: Corrected During Inspection
Initial Penalty: $16,131.00
Current Penalty: $6,000.00
Issuance Date: 05/17/2024
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 10
Report ID: 0521100
Contest Date: 06/11/2024
Final Order: 09/24/2025
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 09/24/2025 | $6,000.00 | Other | ||
| Penalty | C: Contested | 06/12/2024 | $16,131.00 | Serious | ||
| Penalty | Z: Issued | 05/17/2024 | $16,131.00 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1910.147(c)(5)(ii)(C)(1): Protective materials and hardware - Substantial. Lockout devices shall be substantial enough to prevent removal without the use of excessive force or unusual techniques, such as with the use of bolt cutters or other metal cutting tools. On or about February 28, 2024, at an establishment located at N3620 County Road D in New London, WI; employees were exposed to potential caught-in and struck-by hazards while performing setup and maintenance tasks on the Ham Spiral Machines with plug lock out devices, which were easily removable from the pneumatic line.