Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1713850.015
Citation: 01004A
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $16,131.00
Current Penalty: $16,131.00
Issuance Date: 05/21/2024
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 06/17/2024
Gravity: 10
Report ID: 0627100
Contest Date:
Final Order: 06/05/2024
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/05/2024 | $16,131.00 | 06/17/2024 | Other | |
| Penalty | Z: Issued | 05/21/2024 | $16,131.00 | 06/17/2024 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedure did not clearly and specifically specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: On or about November 22, 2023, at the Curve Gang Saw, employees were engaged in servicing and maintenance activities, such as, but not limited unjamming. The lockout and tagout procedure were deficient in that: a) procedures did not include the means to isolate and block the stored energy of the pressure rollers; b) procedures did not include specific procedural steps to control all pneumatic and electrical energy sources.