Violation Detail
Standard Cited: 19100213 C01 Woodworking machinery requirements.
Inspection Nr: 1705601.015
Citation: 01004A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,610.00
Current Penalty: $2,800.00
Issuance Date: 03/18/2024
Nr Instances: 1
Nr Exposed: 14
Abatement Date: 10/16/2024
Gravity: 5
Report ID: 0316700
Contest Date:
Final Order: 04/25/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/25/2024 | $2,800.00 | 10/16/2024 | Serious | |
Penalty | Z: Issued | 03/18/2024 | $4,610.00 | 04/11/2024 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1910.213(c)(1): Circular hand-fed ripsaw(s) were not guarded by an automatically adjusting hood, which completely enclosed that portion of the saw above the table and above the material being cut: a) Cabinet Room - Employees were exposed to amputation hazards while engaged in wood cutting operations utilizing a General table saw (Model 350) that was not guarded, on or about October 23, 2023. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.