Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1678809.015
Citation: 01004A
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $7,032.00
Current Penalty: $7,032.00
Issuance Date: 10/30/2023
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 04/29/2024
Gravity: 5
Report ID: 0626600
Contest Date:
Final Order: 12/01/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/01/2023 | $7,032.00 | 04/29/2024 | Other | |
Penalty | Z: Issued | 10/30/2023 | $7,032.00 | 11/17/2023 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): On or about June 21, 2023, on the west side of the cone feed conveyor, employees were exposed to a caught-by hazard while working near the cone feed conveyor without a guard covering lower portion of the conveyor belt pulley.