Violation Detail
Standard Cited: 19170045 G03 I Cranes and derricks (See also 1917.50).
Inspection Nr: 1674215.015
Citation: 01004A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $15,625.00
Current Penalty: $10,000.00
Issuance Date: 08/04/2023
Nr Instances: 1
Nr Exposed: 7
Abatement Date: 10/02/2023
Gravity: 10
Report ID: 0420100
Contest Date:
Final Order: 08/28/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/28/2023 | $10,000.00 | 10/02/2023 | Serious | |
Penalty | Z: Issued | 08/04/2023 | $15,625.00 | 08/30/2023 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1917.45(g)(3)(i): Each rail-mounted bridge and portal crane located outside an enclosed structure was not fitted with an operable wind-indicating device. (a) P&H 50 ton overhead crane, WATCO River facility, Hawesville, KY: On or about 6/1/2023, and at times prior, the employer exposed employees to possible crushing injuries or death from loss of load control when wind limits were exceeded.