Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1571499.015
Citation: 01004A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,215.00
Current Penalty: $2,500.00
Issuance Date: 03/23/2022
Nr Instances: 2
Nr Exposed: 45
Abatement Date: 04/25/2022
Gravity: 1
Report ID: 0625500
Contest Date:
Final Order: 08/19/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/19/2022 | $2,500.00 | 04/25/2022 | Serious | |
Penalty | Z: Issued | 03/23/2022 | $6,215.00 | 04/25/2022 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: A-B) Depositing Area: On or about January 7, 2022, and at times prior thereto, employees were exposed to a caught-in hazard while working around the streusel depositor with unguarded rotating shafts.