Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1547876.015
Citation: 01004A
Citation Type: Serious
Abatement Date: 11/22/2021
Initial Penalty: $13,653.00
Current Penalty: $0.00
Issuance Date: 09/30/2021
Nr Instances: 1
Nr Exposed: 50
Related Event Code (REC): C
Gravity: 10
Report ID: 0523900
Contest Date:
Final Order: 10/29/2021
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/29/2021 | $0.00 | 11/22/2021 | Serious | |
Penalty | Z: Issued | 09/30/2021 | $13,653.00 | 11/22/2021 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) East Barline area, Screw Machine No. 595045; Energy isolating device(s) were not operated in such a manner as to isolate energy source(s) prior to performing service and/or maintenance work, including but not limited to setup and tooling changes. (b) CNC area, CNC Machine No. 520140 and 520150; Energy isolating device(s) were not operated in such a manner as to isolate energy source(s) prior to performing service and/or maintenance work, including but not limited to setup and tooling changes.