Violation Detail
Standard Cited: 19101200 E01 Hazard Communication.
Inspection Nr: 1479032.015
Citation: 01004A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $2,313.00
Current Penalty: $2,313.00
Issuance Date: 12/09/2020
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 01/13/2021
Gravity: 1
Report ID: 0418300
Contest Date:
Final Order: 01/13/2021
Related Event Code (REC):
Emphasis:
Failure to Abate | |||||||
---|---|---|---|---|---|---|---|
Activity Nr | Issuance | Penalty | Contest | Final Order | |||
1526689 | 09/17/2021 | $5,851.00 | 10/15/2021 |
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
FTA | I: Informal Settlement | 10/15/2021 | $5,851.00 | 1526689.015 | ||
FTA | Z: Issued | 09/17/2021 | $11,702.00 | 1526689.015 | ||
Penalty | Z: Issued | 12/09/2020 | $2,313.00 | 01/13/2021 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) On or about 06/16/2020 - Fabrication Department, the employer did not develop and implement a hazard communication program, exposing employees to chemical bum hazards and fire hazards when working with hazardous chemicals including but not limited to NCF Stone Accelerator, Pectro Stone Brightener, Akemi Transformer, Quartz Toner Plus, and Stain Proof Waterbased Penetrating Sealer (Stain-Repella).