Violation Detail
Standard Cited: 19101026 D01
Inspection Nr: 1458918.015
Citation: 01004A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,374.00
Current Penalty: $2,000.00
Issuance Date: 05/04/2020
Nr Instances: 4
Nr Exposed: 10
Abatement Date: 10/01/2020
Gravity: 5
Report ID: 0522000
Contest Date:
Final Order: 05/19/2020
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/19/2020 | $2,000.00 | 10/01/2020 | Serious | |
Penalty | Z: Issued | 05/04/2020 | $7,374.00 | 08/03/2020 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1910.1026(d)(1): General. Each employer who has a workplace or work operation covered by this section shall determine the 8-hour TWA exposure for each employee exposed to chromium (VI). This determination shall be made in accordance with either paragraph (d)(2) or paragraph (d)(3) of this section. a) On or about January 29, 2020, Cincinnati Fan & Ventilator Company, Inc. did not determine a 8-hour TWA exposure for each employee exposed to chromium (VI) (lung cancer).