Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1450674.015
Citation: 01004A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,048.00
Current Penalty: $2,024.00
Issuance Date: 05/19/2020
Nr Instances: 3
Nr Exposed: 25
Abatement Date: 07/22/2020
Gravity: 1
Report ID: 0420600
Contest Date:
Final Order: 06/15/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/15/2020 | $2,024.00 | 07/22/2020 | Serious | |
| Penalty | Z: Issued | 05/19/2020 | $4,048.00 | 06/22/2020 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a. On or about 12/12/2019, at the fabrication area shear line 1, employees were exposed to a struck by hazard, in that, a series of pulleys at the side of the shear line table did not have a guard to fully enclose the moving parts. b. On or about 12/12/2019, at the fabrication area shear line 2, employees were exposed to a struck by hazard, in that, two pulleys at the side of the shear line table below the point of operation guard did not have a guard to fully enclose the moving parts. c. On or about 12/12/2019, at the fabrication area shear line 2, employees were exposed to a struck by hazard, in that, a series of pulleys at the side of the shear line table did not have a guard to fully enclose the moving parts.