Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1407779.015
Citation: 01004A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,472.00
Current Penalty: $5,209.60
Issuance Date: 12/06/2019
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 03/09/2020
Gravity: 5
Report ID: 0626600
Contest Date: 12/12/2019
Final Order: 02/05/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 02/05/2020 | $5,209.60 | 03/09/2020 | Serious | |
Penalty | C: Contested | 12/12/2019 | $9,472.00 | 12/13/2019 | Serious | |
Penalty | Z: Issued | 12/06/2019 | $9,472.00 | 12/13/2019 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219 (m) and (o). On or about June 11, 2019, in the urethane area of the facility where employees were exposed to a caught-by hazard while working adjacent to an unguarded belt and pulley on a Vantage 1760 lathe.