Violation Detail
Standard Cited: 19100179 E04 Overhead and gantry cranes.
Inspection Nr: 1341898.015
Citation: 01004A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $10,419.00
Current Penalty: $5,210.00
Issuance Date: 02/15/2019
Nr Instances: 1
Nr Exposed: 9
Abatement Date: 03/12/2019
Gravity: 5
Report ID: 0419400
Contest Date: 03/14/2019
Final Order: 06/24/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 06/24/2019 | $5,210.00 | 03/12/2019 | Serious | |
| Penalty | C: Contested | 06/12/2019 | $10,419.00 | 03/12/2019 | Serious | |
| Penalty | Z: Issued | 02/15/2019 | $10,419.00 | 03/12/2019 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1910.179(e)(4): Bridge truck(s) were not equipped with sweep(s) which extended below the top of the rail and projected in the front of the truck wheel(s). (a) Paper Floor - During the period of January 24, 2018 through August 24th, 2018 the House Crane was missing the NE rail sweep allowing employees to be exposed to struck-by hazards.
Translate