Violation Detail
Standard Cited: 19100147 D05 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1308913.015
Citation: 01004A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $6,282.00
Current Penalty: $0.00
Issuance Date: 04/25/2018
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 5
Report ID: 0729300
Contest Date:
Final Order: 05/24/2018
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/24/2018 | $0.00 | Serious | ||
| Penalty | Z: Issued | 04/25/2018 | $6,282.00 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices: The flow valve to pump #3019 in the blast furnace building was not completely closed before lockout work was performed, and the pressure relief valve was not tested to release line water pressure.