Standard Cited: 19100147 C04 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1304632.015
Citation: 01004A
Citation Type: Serious
Abatement Date: 07/06/2018 2
Initial Penalty: $3,880.00
Current Penalty: $2,716.00
Issuance Date: 06/11/2018
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 1
Report ID: 0316400
Contest Date: 07/18/2018
Final Order: 02/02/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | C: Contested | 01/23/2020 | $3,880.00 | 07/06/2018 | Serious | |
Penalty | F: Formal Settlement | 02/02/2019 | $2,716.00 | 07/06/2018 | Serious | |
Penalty | Z: Issued | 06/11/2018 | $3,880.00 | 07/06/2018 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section: (a) 4 Bay: On March 20, 2018 and times prior, the employer has not developed a specific energy control procedure for the Acer E-Mill (model #3VKH-54) for maintenance employees that conduct lockout/tagout on the mill during servicing and maintenance. The Acer E-Mill has multiple energy sources, 240 volt electrical and 95 psi pneumatic pressure.