Violation Detail
Standard Cited: 19100219 C04 II Mechanical power-transmission apparatus.
Inspection Nr: 1236323.015
Citation: 01004A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,338.00
Current Penalty: $3,802.80
Issuance Date: 07/20/2017
Nr Instances: 1
Nr Exposed: 12
Abatement Date: 07/31/2017
Gravity: 5
Report ID: 0625400
Contest Date:
Final Order: 08/15/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/15/2017 | $3,802.80 | 07/31/2017 | Serious | |
Penalty | Z: Issued | 07/20/2017 | $6,338.00 | 07/31/2017 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1910.219(c)(4)(ii): The unused keyway(s) of projecting shaft end(s) were not filled up or covered. On or about May 31, 2017, at the Sumitomo SE180EV injection molding machine conveyor, the rotating unprotected keyway shaft was protruding out approximately 2.5 inches. Employees work and walk by the conveyor with the rotating protruding shaft. Employees exposed to the hazard of being caught-in the rotating protruding shaft.