Violation Detail
Standard Cited: 19260502 D16 V Fall protection systems criteria and practices.
Inspection Nr: 1183641.015
Citation: 01004A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,730.00
Current Penalty: $5,238.00
Issuance Date: 11/22/2016
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 01/11/2017
Gravity: 10
Report ID: 0419700
Contest Date:
Final Order: 12/16/2016
Related Event Code (REC): I
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/16/2016 | $5,238.00 | 01/11/2017 | Serious | |
Penalty | Z: Issued | 11/22/2016 | $8,730.00 | 01/11/2017 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1926.502(d)(16)(v): Personal fall arrest systems, when stopping a fall, did not have sufficient strength to withstand twice the potential impact energy of an employee free falling a distance of 6 feet (1.8 m) or the free fall distance permitted byNote: If the personal fall arrest system meets the criteria and protocols contained in Appendix C to subpart M, and if the system is being used by an employee having a combined person and tool weight of less than 310 pounds (140 kg), a. On or about October 13, 2016 one employee had affixed his personal fall arrest lanyard to a piece of 1/2" steel rebar on the structure. The employee did not understand the ineffective mounting point for his fall protection lanyard.