Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1143960.015
Citation: 01004A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,988.00
Current Penalty: $2,500.00
Issuance Date: 10/17/2016
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 02/15/2017
Gravity: 5
Report ID: 0213900
Contest Date: 11/07/2016
Final Order: 05/19/2017
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | J: ALJ Decision | 05/19/2017 | $2,500.00 | 02/15/2017 | Serious | |
| Penalty | C: Contested | 11/08/2016 | $4,988.00 | 11/10/2016 | Serious | |
| Penalty | Z: Issued | 10/17/2016 | $4,988.00 | 11/10/2016 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) Fairfield Pallet Co. Inc. - 282 Rockville Road, Bridgeton NJ 08302: The Pallet trim system machine had an unguarded pulley, observed on or about 04/28/2016.