Violation Detail
Standard Cited: 19261053 B01 Ladders.
Inspection Nr: 1138899.015
Citation: 01004A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $1,600.00
Current Penalty: $800.00
Issuance Date: 05/19/2016
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 06/01/2016
Gravity: 5
Report ID: 0316400
Contest Date:
Final Order: 06/14/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/14/2016 | $800.00 | 06/01/2016 | Serious | |
Penalty | Z: Issued | 05/19/2016 | $1,600.00 | 06/01/2016 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: (a) Great Teays Car Wash: On or about April 11, 2016, employees were using a 24 foot Werner extension ladder to access the top of the car wash bays. The ladder sat flush with the edge of the bay cross beams and did not extend at least three feet above the upper landing surface.