Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1064409.015
Citation: 01004A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,500.00
Current Penalty: $2,925.00
Issuance Date: 07/24/2015
Nr Instances: 3
Nr Exposed: 2
Abatement Date: 12/03/2015
Gravity: 5
Report ID: 0729300
Contest Date:
Final Order: 08/21/2015
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/21/2015 | $2,925.00 | 12/03/2015 | Serious | |
Penalty | Z: Issued | 07/24/2015 | $4,500.00 | 09/10/2015 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented, and utilized for the control of potentially hazardous energy when employees were engaged in activities under this section: Specific lockout/tagout procedures were not developed, documented, or utilized for machinery including, but not limited to, the following: a/ K.R. Wilson Hydraulic Press, m/n 3700V2-B, s/n 2051. b/ Bliss Mechanical Punch Press, m/n 5012, unknown s/n. c/ HAAS Vertical Machining Center, m/n BF2, s/n 2080.