Violation Detail
Standard Cited: 19100107 C03 Spray finishing using flammable and combustible materials.
Inspection Nr: 1019426.015
Citation: 01004A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $2,800.00
Current Penalty: $2,800.00
Issuance Date: 07/20/2015
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 08/13/2015
Gravity: 10
Report ID: 0830100
Contest Date:
Final Order: 08/11/2015
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/11/2015 | $2,800.00 | 08/13/2015 | Serious | |
Penalty | Z: Issued | 07/20/2015 | $2,800.00 | 08/13/2015 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1910.107(c)(3): Hot surfaces were located in spraying area(s) where deposits of combustible residues could readily accumulate: a) Paint booth; On or about January 22, 2015 and at times prior, employees were exposed to fire and explosion hazards while applying flammable and combustible liquids such as, but not limited to, Ethanol, Propanol, Methyl Propanol, Formaldehyde, Acetone, Butyl Acetate, Methoxy Propanol Acetate and Amorphous Silica (SHER-WOOD Hi-Bild PreCat Lacquer, Flat) to finished cabinets in spraying areas while using an unapproved SOLIEL 750w-1500w heater to provide heat.