Violation Detail
Standard Cited: 19260451 A06 General requirements.
Inspection Nr: 998070.015
Citation: 01004
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $1,600.00
Current Penalty: $1,043.00
Issuance Date: 11/04/2014
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 11/08/2014
Gravity: 5
Report ID: 0625500
Contest Date:
Final Order: 12/16/2014
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/16/2014 | $1,043.00 | 11/08/2014 | Serious | |
| Penalty | Z: Issued | 11/04/2014 | $1,600.00 | 11/08/2014 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1926.451(a)(6): Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory Appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section: On or about October 01, 2014, employee was exposed to fall hazards of greater than 10 feet in height to the ground level below when working from a scaffold which was not designed and/or constructed by a qualified person when the pole scaffold was constructed using 2X6's nailed to the wall, 2X4's 20 feet in length used for pole legs and no cross bracing, while installing the thermal paper on the front of the residential home.