Violation Detail
Standard Cited: 19100147 D04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 991351.015
Citation: 01004
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,000.00
Current Penalty: $5,600.00
Issuance Date: 11/03/2014
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 01/16/2015
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 11/25/2014
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/25/2014 | $5,600.00 | 01/16/2015 | Serious | |
Penalty | Z: Issued | 11/03/2014 | $7,000.00 | 11/21/2014 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: During the week of August 18, 2014, the employer failed to ensure that employees lockout the power distribution panel prior to entering the spinner shaft area of Rolling Mill C0074 to repair the chain and sprocket.