Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 965945.015
Citation: 01004
Citation Type: Serious
Abatement Date: 04/18/2014 2
Initial Penalty: $2,380.00
Current Penalty: $1,785.00
Issuance Date: 04/10/2014
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): C
Gravity: 5
Report ID: 0111100
Contest Date:
Final Order: 04/30/2014
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/30/2014 | $1,785.00 | 04/18/2014 | Serious | |
Penalty | Z: Issued | 04/10/2014 | $2,380.00 | 04/18/2014 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: Rail Unloading Area - The tail end of the drum and belt had a five inch long by two inch diameter horizontal shaft that was not guarded.