Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 955136.015
Citation: 01004
Citation Type: Serious
Abatement Date: 07/29/2014 2
Initial Penalty: $7,000.00
Current Penalty: $7,000.00
Issuance Date: 06/09/2014
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): A
Gravity: 10
Report ID: 0111400
Contest Date:
Final Order: 06/20/2014
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/20/2014 | $7,000.00 | 07/29/2014 | Serious | |
Penalty | Z: Issued | 06/09/2014 | $7,000.00 | 07/29/2014 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: Location: Shucking Machine The shucking machine was not de-energized and locked out as per company's lock out/tag out procedures during sanitation. An employee cleaning out a drainage pipe attached to a steam valve was fatally injured when he was caught in a rotating shaft.