Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 921325.015
Citation: 01004
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $2,000.00
Current Penalty: $1,000.00
Issuance Date: 11/21/2013
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 12/04/2013
Gravity: 5
Report ID: 0420600
Contest Date:
Final Order: 12/16/2013
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/16/2013 | $1,000.00 | 12/04/2013 | Serious | |
| Penalty | Z: Issued | 11/21/2013 | $2,000.00 | 12/04/2013 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) at 2401 Airport Road Plant City (FL), employees performing various job tasks utilizing a Bridgeport Milling Machine, Series I and a Enco Milling Machine with exposed moving parts located in the head area, as observed on or about July 19, 2013.