Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 909244.015
Citation: 01004
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $3,500.00
Current Penalty: $2,450.00
Issuance Date: 09/24/2013
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 10/11/2013
Gravity: 5
Report ID: 0316400
Contest Date:
Final Order: 11/07/2013
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/07/2013 | $2,450.00 | 10/11/2013 | Serious | |
| Penalty | Z: Issued | 09/24/2013 | $3,500.00 | 10/11/2013 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle: a. Prep shop Cincinnati shear: Employees used a Cincinnati 12' shear to cut metal plate that had a guard 1-3/4" to 2" above the table and within 3" of the point of operation. The guard would not prevent employees from coming into contact with the hold downs and shear blade during operation of the shear, as determined on 5/30/13. Abatement Certification Required For This Item.