Violation Detail
Standard Cited: 19100272 J03 Grain handling facilities.
Inspection Nr: 907832.015
Citation: 01004
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $2,975.00
Current Penalty: $1,785.00
Issuance Date: 06/26/2013
Nr Instances: 1
Nr Exposed: 9
Abatement Date: 08/08/2013
Gravity: 5
Report ID: 0522500
Contest Date:
Final Order: 07/17/2013
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/17/2013 | $1,785.00 | 08/08/2013 | Serious | |
| Penalty | Z: Issued | 06/26/2013 | $2,975.00 | 07/31/2013 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.272(j)(3): The use of compressed air to blow dust from ledges, walls, and other areas shall only be permitted when all machinery that presents an ignition source in the area is shut-down, and all other known potential ignition sources in the area are removed or controlled: a. In the processing plant, compressed air was used to blow fugitive grain dust from upper surfaces when the plant equipment was in operation and ignition sources were not removed or controlled.