Violation Detail
Standard Cited: 19100027 D01 III Scaffolds and rope descent systems.
Inspection Nr: 498799.015
Citation: 01004
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 11/15/2012
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 12/12/2012
Gravity: 5
Report ID: 0418400
Contest Date:
Final Order: 12/12/2012
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 11/15/2012 | $0.00 | 12/12/2012 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.27(d)(1)(iii): Cages did not extend a minimum of 42 inches above the top of the landing. A) Roof of dump shed, on or about June 29, 2012, the cage of the fixed metal ladder used to access the roof of the shed did not extend 42 inches above the landing surface, exposing employees to a fall hazard of approximately 19 feet.
Translate