Powered by GoogleTranslate

Violation Detail

Standard Cited: 50104 A General Duty

Inspection Nr: 315611160

Citation: 01004

Citation Type: Serious

Abatement Status: X

Initial Penalty: $875.00

Current Penalty: $525.00

Issuance Date: 09/28/2011

Nr Instances: 1

Nr Exposed: 4

Abatement Date: 10/06/2011

Gravity: 07

Report ID: 0352440

Contest Date:

Final Order:

Related Event Code (REC): R

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 01/18/2012 $525.00 10/06/2011 Serious  
Penalty Z: Issued 09/28/2011 $875.00 10/06/2011 Serious  

Text For Citation: 01 Item/Group: 004 Hazard: DUST&FUMES

Labor and Employment Article, Section 5-104(a): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: (a)Date of Violation:08/02/11 Location:Sanding/Grinding Room Equipment:Donaldson Torit ECB-3 Condition:Employees were exposed to fire and explosion hazards from the generation of combustible fines while grinding, sanding, and buffing a variety of aluminum metal parts. In the Environmental Control Booth the aluminum dust was collected with a dry type collection system located inside which recirculated the air back into the work area. Among other methods, one feasible and acceptable abatement method to correct this hazard is to relocate the dry type dust collection system outside the building in a safe location. Perform a process hazard analysis/assessment on sanding aluminum products and the dust collection systems. Obtain a certification verifying the design, installation, operation, and maintenance of aluminum explosive/combustible dust collection system meets all applicable standards including, but not limited to, NFPA 484 Standard for Combustible Metals, 2009 Edition. (b)Date of Violation:08/02/11 Location:Outside Rear of Building Equipment:Dustkop and Mistkop Cyclone Collector Model #20T31-D1-SP Condition:Employees were exposed to fire and explosion hazards from the generation of combustible aluminum dust while sanding aluminum sheet metal parts with the dry type Time Saver Machine connected to a cyclone collector located outside the building. Dust collector was not properly bonded and grounded, lacked proper deflagration venting, lacked an abort valve, was not emptied daily, and lacked proper filter maintenance for dust collector. Among other methods, one feasible and acceptable abatement method to correct this hazard is to verify the design, installation, operation and maintenance of the aluminum dust collection system meets all applicable standards including, but not limited to, NFPA 484 Standard for Combustible Metals, 2009 Edition and NFPA 69 Standard on Explosive Prevention Systems 2008 Edition. Abatement documentation (photogrpahs, receipts, copies of programs, training certification, etc.) is required for this item.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close