Powered by GoogleTranslate

Violation Detail

Standard Cited: 19100119 F01 Process safety management of highly hazardous chemicals.

Inspection Nr: 312412356

Citation: 01004

Citation Type: Serious

Abatement Status: X

Initial Penalty: $56,000.00

Current Penalty: $3,000.00

Issuance Date: 04/28/2010

Nr Instances: 1

Nr Exposed: 24

Abatement Date: 06/01/2014

Gravity: 10

Report ID: 0854910

Contest Date: 05/27/2010

Final Order: 10/23/2013

Related Event Code (REC):

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty P: Petition to Mod Abatement 04/18/2014 $3,000.00 06/01/2014 Serious  
Penalty F: Formal Settlement 10/23/2013 $3,000.00 02/20/2014 Serious  
Penalty Z: Issued 04/28/2010 $56,000.00 06/03/2010 Willful  

Text For Citation: 01 Item/Group: 004 Hazard: REFINERY

29 CFR 1910.119(f)(1) The employer shall develop and implement written operating procedures that provide clear instructions for safely conducting activities involved in each covered process consistent with the process safety information. A. The employer did not ensure written operating procedures related to the facility's car seal program were implemented. This violation was identified during onsite inspections from November 2009 to March 2010, Silver Eagle Refining Inc., 2355 South 110 West, Woods Cross, UT, 84087. The employer developed a car seal program signed by plant management on June 8, 2004, yet requirements of this policy to car seal or lock open any intervening valve were not carried out. As part of the Owner-User Program, the facility was required to report to the Utah State Division of Boilers and Elevators they were complying with their internal car seal program. Although the program and policy had been developed, the employer did not follow the requirements of car sealing or locking open any intervening valve. During field inspections, more than 50 intervening valves were noted not to be car sealed or locked open. Examples of such include, but not limited to, Valve PF 14192 protecting Vessel Serial #15195. By not implementing and following the facility's internal car seal program and procedure, valves could be inadvertently closed isolating relief valves. In the event of an equipment failure due to an intervening valve being closed, employees could be exposed to hazardous situations such as fires, explosions, and/or chemical releases which can result in serious injury or death. This may be a system-wide occurrence that requires evaluation of all intervening valves throughout the facility.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.