Violation Detail
Standard Cited: 95012901
Inspection Nr: 307318410
Citation: 01004
Citation Type: Serious
Abatement Status: X
Initial Penalty: $263.00
Current Penalty: $184.10
Issuance Date: 01/07/2004
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 02/25/2004
Gravity:
Report ID: 0453730
Contest Date:
Final Order:
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/20/2004 | $184.10 | 02/25/2004 | Serious | |
| Penalty | Z: Issued | 01/07/2004 | $263.00 | 02/25/2004 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard: UNAPEQUIP
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish to each of his employees conditions of employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: a)upholstery packing department ! the rated load of a monorail hoist system was not marked on each side of the monorail. REFERENCE:ANSI B30.11-1980, Chapter 11-1, Section 11-1.1, Markings, Paragraph 11-1.1.2 Rated Load Markings - Monorails. The rated load shall be marked on each side of the monorail to indicate the maximum load allowed. NOTE:Among other methods of abatement, one feasible and acceptable method to correct this hazard is label the hoist monorail as required by the above listed reference.
Translate