Violation Detail
Standard Cited: 19260451 E05 I General requirements.
Inspection Nr: 1880082.015
Citation: 01004
Citation Type: Serious
Abatement Status: Quick Fix
Initial Penalty: $4,965.00
Current Penalty: $2,979.00
Issuance Date: 04/10/2026
Nr Instances: 3
Nr Exposed: 3
Abatement Date:
Gravity: 10
Report ID: 0419400
Contest Date:
Final Order: 05/05/2026
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/05/2026 | $2,979.00 | Serious | ||
| Penalty | Z: Issued | 04/10/2026 | $4,965.00 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1926.451(e)(5)(i): Ramps and walkways 6 feet (1.8 m) or more above lower levels did not have guardrail systems that comply with subpart M of this part -- Fall Protection: (a) South/east side of building - On or about March11, 2026, the employer had employees use the scaffolding walkway planking to get from one set of scaffolding to another that was not guarded exposing employees to fall hazards.